GMH 3692 Air oxygen meter without sensor
features
- Alarm monitoring with integrated horn
- Ambient pressure compensation with integrated barometer
Temperature compensation : automatic via temperature sensor integrated in the sensor housing. Air pressure compensation: The O2 concentration is automatically compensated with the integrated pressure sensor.
Calibration : 1-point calibration: easiest adjustment to atmospheric air. (Device is adjusted to 20.9% by pressing a button).
2- / 3-point calibration : first point in air (20.9%), second and third 0 or 100%. Calibration Interval: After a selectable period of time (1 ... 365 days or inactive) a recalibration is requested.
GMH 3695: additional calibration history Analogue output (only GMH 3695): 0 ... 1 V, freely scalablePressure connector (only GMH 3695): for pressure compensationData logger (only GMH 3695): Cyclic: 8000 data sets, cycle selectable: 1 s ... 60 min Single: 1000 data records, with measuring point input
applications
Biochemistry:
Oxygen monitoring in incubators for the cultivation of cell cultures. Monitoring the fermentation of fruits in fermentation plants, etc.
Medical Technology:
Monitoring the oxygen concentration of respirators; Breath control; Oxygen concentration monitoring eg in oxygen tents, etc.
Food technology:
Checking the residual oxygen in packaging (eg coffee, tea, MAP, etc.). Monitoring the oxygen content of critical production processes and storage.
Air conditioning and ventilation technology:
Oxygen measurement; Air quality monitoring; Oxygen concentration measurement in closed ventilation systems, etc.
Sports:
Immersion gas test: Checking the oxygen concentration in nitrox, trimix or similar gas mixtures
Note:
Not suitable for use in "underwater applications" (rebreather etc.) Air oxygen meter without sensor
Use | Hand-held devices |
---|---|
Measured Variable | Air oxygen |
Operating conditions | Temperature: 0 to +50 ° C Relative humidity: 0 to 95% rh (non-condensing) |
Accuracy | O2 concentration: ± 0.1% ± 1 digit Temperature: ± 0.1 ° C ± 1 digit Air pressure: ± 3 hPa or 0.1% of MW (higher applicable) |
Measuring range | O2 concentration: 0.0 ... 100.0% O2 (gaseous), 0 ... 1100 hPa O2 Temperature: -5.0 ... +50.0 Air pressure: GMH 3692: 10 ... 1200 hPa GMH 3695: 300 ... 5000 hPa |
Power supply | 9 V battery as well as additional d.c. connector for external 10.5 ... 12 V direct voltage supply. (suitable power supply:GNG10/3000) |
Battery Life | approx. 300 h |
Control Elements | 6 Folientaster für Ein-/Aus-Schalter, Auswahl des Mess-bereiches, Min- und Max-Wert-Speicher, Hold-Funktion, Kalibration, usw. |
Data transfer | USB cable, Serial Interface |
Dimensions | 142 x 71 x 26 mm |
Case | ABS |
Weight | ca. 160 g (incl. battery) |